TM 10-3930-675-20-10042 00-5TOPHANDLER SLEWING TROUBLESHOOTING - CONTINUED0042 00Table 3. Error Code 255 - Tophandler Clockwise Slewing, Wiring Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 255 - Tophandler ClockwiseSlewing, Wiring Circuit Failure - Continuedb. If voltage is not present,enter “DIAG ATTACH-MENT 12 (16)” menu andcheck current of SLEWCW OUTPUT. Currentshould be present withjoystick activated to slewclockwise.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 4. Error Code 256 - Tophandler Clockwise Slewing, Component Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 256 - Tophandler ClockwiseSlewing, Component Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damaged wires(WP 0111 00).2. Disconnect electricalconnector 6008 fromtophandler clockwise slewingsolenoid. Place ignitionswitch to ON position. Errorcode 255 will be displayed.Perform voltage check.If 20-25V is present at connector6008, replace clockwise slewingsolenoid (WP 0169 00).3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to OFF position andcheck continuity betweenconnector 6008 pin 1 and pin2 and between connector6008 pin 1 and pin 2 andchassis.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.DIAG TOP LIFT 12(16)OUTPUT/INPUTSLEW CW 0mA 0mASLEW CCW 0mA 0mA