TM 10-3930-675-20-20072 00-6INSTRUMENT PANEL SWITCHES, GAGES, AND PANEL LAMPSREPLACEMENT - CONTINUED0072 00GAGE REMOVAL1.Perform steps 1 and 2 of RockerSwitch Removal to gain access to rear of gage.2.To remove gage lamp, refer to InstrumentPanel Lamp Removal.NOTEPerform steps 3 and 4 for fuel gage.3.Disconnect instrument panel wiring harness connector (25) from rear of gage (19).4.Remove retainer (20) and gage (19) from switch/gage panel (1).NOTEPerform steps 5 and 6 for hour meter gage.5.Disconnect instrument panel wiring harness connector (24) from rear of gage (21).6.Remove two nuts (23), retainer (22), and gage (21) from switch/gage panel (1).GAGE INSTALLATIONNOTEPerform steps 1 and 2 for hour meter gage.1.Install gage (21) to switch/gage panel (1) with retainer (22) and two nuts (23).2.Connect instrument panel wiring harness connector (24) to gage (21).NOTEPerform steps 3 and 4 for fuel gage.251920121222324