TM 10-3930-675-20-2
0111 00-1
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS
0111 00
THIS WORK PACKAGE COVERS
Multiple-Pin Connector Identification Diagrams
Connector Repair
Sealed Connector Repair
Receptacle Connector Repair
Waterproof Connector Repair
Military Connector Repair
Ring Terminal Repair
Splicing Wires
Electrical Ground Points
Multimeter Usage
Relay Inspection and Test
INITIAL SETUP
Tools and Special Tools
Tool kit, general mechanics (Item 31, WP 0204 00)
Heater, gun (Item 12, WP 0204 00)
Multimeter, digital (Item 18, WP 0204 00)
Tool kit, electrical connector repair (Item 30, WP 0204
00)
Materials/Parts
Cloth, abrasive (Item 5, WP 0203 00)
Detergent (Item 11, WP 0203 00)
Grease, electrically conductive (Item 17, WP 0203 00)
Tag, marker (Item 28, WP 0203 00)
Tubing, heat shrinkable (Item 30, WP 0203 00)
CAUTION
Splicing is prohibited on any wire within the RTCH electronic CAN-BUS system. Refer to WP 0199 00 for
CAN-BUS system diagrams.
NOTE
Use electrically conductive grease on unprotected (exposed to weather) electrical connectors before connec-
tions are made.