TM 10-3930-675-24-1
TROUBLESHOOTING INTRODUCTION - CONTINUED
0004 00
DIAG ATTACHMENT - CONTINUED
DIAG ATTACH
13(16)
Signals to ECU 791 connector 3 from the tilt valve
OUTPUT
INPUT
solenoids.
TILT IN
0mA
0mA
Output = Target value, Input = Actual value
TILT OUT
0mA
0mA
Activating tilt function; the target value appears.
The actual amperage will rise to closely match the
target value.
DIAG ATTACH
14(16)
Signals to ECU 791 connector 3 from the oscillation
OUTPUT
INPUT
valve solenoids.
OSC. RI
0mA
0mA
Output = Target value, Input = Actual value.
OSC. LE
0mA
0mA
Activating oscillate function; the target value appears.
The actual amperage will rise to closely match the
target value.
DIAG ATTACH
15(16)
Signals from ECU 791 connector 3 to float lock valve
ACTIVE
OUTPUT
INPUT
solenoids.
OSC.
24.00V
900mA
Voltage (24V) to solenoids and actual amperage
TILT
24.00V
900mA
through solenoid coils when float lock function is
activated.
DIAG STEERING
DIAG STEERING
1(16)
Signals from steering mode buttons to ECU 792.
DIG IN
1 = 24V signal, 0 = no signal.
STEERING
2WD
0
STEERING
4WD
0
STEERING
CRAB
0
0004 00-14