TM 10-3930-675-24-1
OVERLOAD PROTECTION TROUBLESHOOTING
THIS WORK PACKAGE COVERS
Error Code 134 - Right Lift Cylinder Pressure Sensor or
Error Code 130 - Overload Protection System Failure
Circuit Failure
Error Code 131 - Boom Extension Sensor or Circuit
Failure
Error Code 135 - Left Lift Cylinder Piston Pressure Sen-
Error Code 132 - Boom Angle Sensor or Circuit Failure
sor or Circuit Failure
Error Code 133 - Left Lift Cylinder Pressure Sensor or
Error Code 136 - Right Lift Cylinder Piston Pressure
Circuit Failure
Sensor or Circuit Failure
Error Code 210 - Tophandler Angle Sensor or Circuit
Failure
INITIAL SETUP
References
TM 10-3930-675-10
Current Supply (A34738.0200) (WP 0048 00-31)
ECS Attachment (A34652.0200) (WP 0048 00-23)
ECS Electrical Servo (A34648.0200) (WP 0048 00-5)
NOTE
Refer to WP 0004 00 for additional troubleshooting guidance, information, and illustrations that
locate critical components.
Refer also to illustrations at end of work package for component location.
Table 1. Error Code 130 - Overload Protection System Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 130 - Overload Protection System Overload protection system is not Troubleshoot original error codes
Failure.
working due to an earlier failure 131 to 136.
(error codes 131 to 136) on any
component related to the
overload protection system.
Hydraulic speeds are limited and
the error code will flash on the
display every 5 seconds.