TM 10-3930-675-24-2
CIRCUIT BREAKERS AND RELAYS REPLACEMENT - CONTINUED
0074 00
CAB DISTRIBUTION BOX CIRCUIT BREAKERS AND RELAYS INSTALLATION
NOTE
Perform step 1 to install each of two relays.
1.
Connector connector (15) of wiring harness (11) to relay (14) and install screw (16).
NOTE
Perform step 2 to install each of 15 relays.
2.
Connect relay (12) to terminal block (13) of relay panel (6).
NOTE
Each of 34 circuit breakers is installed the same way.
3.
Connect three connectors (10) of wiring harness (11) to rear of circuit breaker (9).
4.
Push circuit breaker (9) upward through hole in circuit breaker panel (4).
5.
Install circuit breaker (9) with two washers (8) and screws (7).
4
7,8
434-4009
0074 00-5