TM 10-3930-675-24-2
SPREADER 20 AND 40 FOOT ADJUSTMENT - CONTINUED
0169 00
MEASUREMENT AND ADJUSTMENT - 20 FT - CONTINUED
NOTE
Twistlocks can be moved side to side in any horizontal position, by hand, to position them in middle of cutout.
4.
Use override switch to operate twistlocks (3) to locked position. Green light on boom will be lit (TM 10-3930-675-10).
NOTE
When twistlocks are in the locked position, spreader function is deactivated.
5.
Ensure twistlocks (3) are in middle of cutout position in bottom of spreader section (2).
3
2
434-40157
6.
Measure from inside flat edge of one twistlock (3) to other twistlock outer flat edge.
NOTE
Measurement should be 230 7/16 in. 1/8 in. (5,853 mm 3 mm).
434-40158
0169 00-2