TM 10-3930-675-24-2
BOOM AND TOPHANDLER CALIBRATION - CONTINUED
0259 00
CALIBRATION - CONTINUED
Boom Calibration, Boom Angle, Lowered Position (Menu 1 of 10).
2.
a.
Lower boom to lowest position.
b.
Allow ECS display to stabilize, then press "Enter".
c.
ECS display screen should look as shown:
CALIBR SERVO
1 (10)
LOWER
MINIMUM
XXX
BOOM ANGLE
XXX
Range 600-800
d.
Press right arrow button to advance through remaining calibration menus.
Boom Calibration, Tophandler Tilt Position (Menu 2 of 10).
3.
a.
Lower boom to lowest position.
b.
Level tophandler with ground.
c.
Allow ECS display to stabilize, then press "Enter".
d.
ECS display screen should look as shown:
CALIBR SERVO
2 (10)
LOWER
MINIMUM
XXX
TILT ANGLE
XXX
Range 200-400
e.
Press right arrow button to advance through remaining calibration menus.
Boom Calibration, Boom Angle, Raised Position (Menu 3 of 10).
4.
a.
Raise boom to maximum height and fully retract with tophandler level with ground.
b.
Allow ECS display to stabilize, then press "Enter".
c.
ECS display screen should look as shown:
CALIBR SERVO
3 (10)
LIFT
MAXIMUM
XXX
BOOM ANGLE
XXX
Range 200-400
d.
Press right arrow button to advance through remaining calibration menus.
0259 00-2