TM 10-3930-675-24-2
BOOM AND TOPHANDLER CALIBRATION - CONTINUED
0259 00
CALIBRATION - CONTINUED
5.
Boom Calibration, Tophandler Tilt Angle (Boom in Raised Position) (Menu 4 of 10).
a.
Raise boom to maximum height, fully retract, and level tophandler with ground.
b.
Allow ECS display to stabilize, then press "Enter".
c.
ECS display screen should look as shown:
CALIBR SERVO
4 (10)
LIFT
MAXIMUM
XXX
TILT ANGLE
XXX
Range 600-800
d.
Press right arrow button to advance through remaining calibration menus.
6.
Boom Calibration, Retracted Position (Menu 5 of 10).
a.
Raise boom to maximum height and fully retract.
b.
Allow ECS display to stabilize, then press "Enter".
c.
ECS display screen should look as shown:
CALIBR SERVO
5 (10)
BOOM
XXX
MIN EXTENSION
Range 35-150
XXX
d.
Press right arrow button to advance through remaining calibration menus.
7.
Boom Calibration, Extended Position (Menu 6 of 10).
a.
Fully extend boom.
b.
Allow ECS display to stabilize, then press "Enter".
c.
ECS display screen should look as shown:
CALIBR SERVO
6 (10)
BOOM
XXX
MAX EXTENSION
XXX
Range 400-550
d.
Press right arrow button to advance through remaining calibration menus.
0259 00-3