TM 10-3930-675-24-2
HYDRAULIC SYSTEM VALVE MAINTENANCE - CONTINUED
0263 00
SERVO PRESSURE REGULATOR VALVE (6043) REMOVAL - CONTINUED
5.
Remove three hoses (32) and O-rings (33) from valve (27). Discard O-rings.
6.
Remove three fittings (31) from valve (27).
26
27
28,29,30
31
32,33
434-40201
SERVO PRESSURE REGULATOR VALVE (6043) INSTALLATION
NOTE
Refer to General Maintenance Instructions (WP 0284 00) for complete instructions on connecting
hydraulic hoses and applying proper torque.
Perform step 1 to install fittings removed from old valve, if a new valve is being installed.
1.
Install three fittings (31) on valve (27).
2.
Lubricate and install three new O-rings (33).
3.
Install and tighten three hoses (32) on valve (27).
4.
Install valve (27) to mounting plate (26) with two bolts (28), washers (30), and nuts (29). Tighten in accordance with
5.
Install clamps and new tiedown straps as needed, in same position as noted during removal.
6.
At hydraulic reservoir, open any ball valve that may have been closed.
7.
8.
Start engine (TM 10-3930-675-10) and check for leaks.
9.
10.
Move cab back to operational position (TM 10-3930-675-10).
0263 00-7