TM 5-3810-306-34
PUMP DISCONNECT INSTALLATION
TOOLS:
SUPPLIES:
EQUIPMENT CONDITIONS:
Rear decking removed. (Refer to TM 5-3810-306-20.)
Three-Section hydraulic pump removed.
Negative battery cable disconnected at shunt.
(Refer to TM 5-3810-306-20.)
REMOVAL:
1. REMOVE PUMP DISCONNECT (1).
a. Pull pump disconnect (1) off studs.
b. Remove and discard gasket (2).
c. Cover opening
to
prevent
dirt
from
entering.
INSTALLATION:
1. CLEAN
PUMP
DISCONNECT
MATING
SURFACES OF GASKET MATERIAL.
2. INSTALL PUMP DISCONNECT (1).
WARNING
Eye contact with silicone RTV
materials may cause irritation. If eye
contact takes place, flush the eyes
with water for 15 minutes and have
the eyes examined by a doctor.
a. Apply silicone sealant to gasket (2).
b. Position new gasket (2) and
pump
disconnect (1) on mounting studs.
13-40