TM 5-3810-306-34
ROLLER/CABLE GUIDE INSTALLATION
SUPPLIES: None
EQUIPMENT CONDITIONS:
Negative battery cable disconnected at shunt. (Refer to TM 5-3810-306-20.)
Length cable disconnected at boom nose receptacle and retracted into length/angle cable
REMOVAL:
1. REMOVE ROLLER GUIDE (1).
a. Remove nuts (2) from capscrews (3).
b. Remove capscrews (3) and roller guide (1) from
lower boom bracket.
2. REMOVE CABLE GUIDE (4).
a. Remove nuts (5) from capscrews (6).
b. Remove capscrews (6) and cable guide (4) from
upper boom bracket.
INSTALLATION:
1. POSITION CABLE GUIDE (4) ON UPPER BOOM
BRACKET AND SECURE WITH BOLTS (6) AND
NUTS (5).
4. CONNECT NEGATIVE BATTERY CABLE
AT
2. POSITION ROLLER GUIDE (1) ON LOWER BOOM
SHUNT. (REFER TO TM 5-3810-306-20.)
BRACKET AND SECURE WITH BOLTS (3) AND
NUTS (2).
5. LOOSEN NUTS (2) AND (5), AND ADJUST
ROLLER/CABLE GUIDES (1) AND (4) FOR
3. REROUTE LENGTH CABLE AND CONNECT AT
SMOOTH OPERATION OF LENGTH CABLE.
BOOM NOSE RECEPTACLE. (REFER TO PAGE
TIGHTEN
NUTS
(2)
AND
(5)
AFTER
ADJUSTMENT.
END OF TASK
14-22