TM 5-3810-306-34
LENGTH CABLE INSTALLATION
SUPPLIES: None
EQUIPMENT CONDITIONS:
Negative battery cable disconnected at shunt. (Refer to TM 5-3810-306-20.)
Length/angle cable reel assembly removed. (Refer to page 14-10.)
REMOVAL:
1. DISCONNECT WIRES OF LENGTH CABLE (2)
FROM TERMINALS 17 AND 18 ON SLIP RING (1)
IN CABLE REEL ASSEMBLY (4).
2. UNWIND LENGTH CABLE (2) AND LOOSEN
STRAIN RELIEF CONNECTOR NUT ON AXLE IN
CENTER OF CABLE DRUM (3). PULL REMAINDER
OF LENGTH CABLE (2) FROM CABLE REEL
ASSEMBLY (4).
INSTALLATION:
1. PUSH NEW LENGTH CABLE (2) THROUGH
STRAIN RELIEF CONNECTOR ON AXLE OF
CABLE DRUM (3), AND UP THROUGH CABLE
REEL ASSEMBLY (4) AND SLIP RING (1).
TIGHTEN STRAIN RELIEF CONNECTOR NUT.
2. PREPARE BOTH ENDS OF LENGTH CABLE (2)
AS SHOWN. TWIST SHIELD INTO A SINGLE
CONDUCTOR ONCE SEPARATED.
3. CONNECT LENGTH CABLE (2) TO SLIP RING (1)
(SHIELD TO TERMINAL 18 AND CORE TO
TERMINAL 17).
4. TURN CABLE DRUM (3) CLOCKWISE (AS
MOUNTED) TO WIND LENGTH CABLE (2) ONTO
DRUM. SECURE FREE END OF LENGTH CABLE
(2) TO CABLE DRUM (3).
5. INSTALL
LENGTH/ANGLE
CABLE
REEL
END OF TASK
14-16