TM 55-8145-201-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model SC-219.
NOTE
If the equipment must be kept in continuous operation, do only the procedures that can
be done without disturbing operation. Make complete checks and services when the
equipment is shut down.
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable If:
Check/Service
EXTERIOR
1
Weekly
Refrigeration loose
a. Check for mounting
Mounting bolts damaged or
Unit
hardware.
missing.
b Check security of power cable
connection.
b. Perform Weekly PMCS on
refrigeration unit (TM 9-4110-252-
14).
2
Weekly
a. Check for loose, missing or
Mounting bolts damaged,
damaged mounting hardware.
loose or missing.
b. Perform Weekly PMCS on
3
Weekly
Fuel Tank
a. Check fuel tank for loose or
Mounting straps loose,
missing attaching hardware.
cracked or missing.
b. Inspect fuel tank for corrosion.
Fuel tank leaks.
Fuel lines cracked, split or
and leakage.
leaking
4
Weekly
Temperature
a. Inspect temperature sensing tube
Sensing line kinked or
Recorder
for dents, kinks and punctures.
punctured.
b. Check for loose mounting
hardware.
INTERIOR
5
Weekly
Temperature
a. Inspect sensing bulb r dents,
Sensing bulb damaged.
Recorder
kinks in sensing line, and obvious
Sensing Bulb
damage.
b. Check security of mounting
Missing mounting screws.
hardware.
4-10