TM 55-8145-201-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model SC-219 - cont.
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable If:
Check/Service
EXTERIOR
6
Monthly
Inspect for cracked, bent or broken
Frame or welds cracked.
Container Frame
corner fittings and frame members.
INTERIOR
7
Monthly
Inspect for bare metal and corrosion.
Container Frame
Section IV. UNIT TROUBLESHOOTING PROCEDURES
4-10. INTRODUCTION.
This section provides the troubleshooting information for the Refrigerated Container at the Unit Maintenance level. It
consists of the symptom index, listing the most common malfunction symptoms, and the troubleshooting table, Table 4-2.
This table repeats the malfunctions, and provides the procedural steps and corrective actions necessary to return the
system to operational readiness.
4-11. TROUBLESHOOTING.
a. The troubleshooting table lists the common malfunctions which you may find during operation of the
refrigerated container. You should perform the tests, inspections and corrective actions in the order they
appear in the table.
b. This table cannot list all the malfunctions that may occur, all the tests or inspections needed to find the fault,
or all the corrective actions needed to correct the fault. If the equipment malfunction is not listed or actions
listed do not correct the fault, notify your supervisor.
c.
Refer to TM 9-4110-252-14 or troubleshooting malfunctions on the refrigeration unit.
d. Refer to TM 5-6115-585-12/34 for troubleshooting malfunctions on the generator set.
4-12. MALFUNCTION INDEX.
Malfunction
Page
1
Rear Doors Will Not Close....................................................... .....................................
2
Water Will Not Drain from Container Floor ..................... ..............................................
3
Temperature Recorder Does Not Record or Does Not Record Properly ............. ...........
4
Temperature Inside Container Will Not Stabilize .............................. ............................
5
Generator Set Not Operating Properly .........................................................................
4-11