TM 55-8145-202-14
4-14.
IDENTIFICATION PLATE - Continued
(2) Align mounting holes in identification plate (2). Install four drive rivets (1) and identification plate (2).
4-15.
TEMPERATURE RECORDER (THERMOMETER) REPLACEMENT.
This task covers:
a. Removal
b. Installation
c. Adjustment
INITIAL SET-UP:
Tools:
Materials/Parts:
General Mechanics Tool Kit (Item 1, App B)
Lockwashers (4) (Item 13, App H)
Equipment Condition:
Refrigeration unit shutdown (TM 9-4110-258-13)
a.
Removal.
CAUTION
To prevent damage to sensing element, do not bend or kink element tubing.
(1) Remove two screws (1) from thermometer element (2) from temperature recorder (3).
(2) Remove four cap screws (4), lock nuts (5) and temperature recorder (3) from container.
(3) Remove four cap screws (6), lockwashers (7) and L-brackets (8) from temperature recorder (3).
4-10