TM 55-8145-202-14
4-16.
THERMOMETER ELEMENT - Continued
d.
Installation.
CAUTION
To prevent damage to thermometer element, do not bend or kink element tubing.
(1) Carefully push element bulb (11) and tubing (12) through wall grommet (13). Carefully bend tubing to
position bulb on container wall.
(2) Install two clamps (10) on element bulb (11) and secure two sheet metal screws (9).
(3) Position thermometer element (7) on temperature recorder (8).
(4) Install two screws (6) on thermometer element (7).
NOTE
FOLLOW-ON MAINTENANCE
4-17.
FUEL TANK AND CONNECTIONS.
This task covers:
a. Removal
b. Disassembly
c. Cleaning
d. Inspection
e. Repair
f. Assembly
g. Installation
INITIAL SET-UP:
Tools:
General Mechanics Tool Kit (Item 1, App B)
Equipment Condition:
Materials/Parts:
Refrigeration unit shutdown (TM 9-4110-258-13)
Lockwasher (5) (Item 2, App H)
Dry cleaning solvent (Item 7, App E)
a.
Removal.
WARNING
To prevent injury to personnel, damage to equipment, or fire make sure fuel tank is empty before
working on fuel tank.
NOTE
Fuel line is not supplied with container.
Refer to TM 5-6115-58512/34 for specific fuel line
maintenance instructions.
4-14