CORRECTIVE ACTION - Continued
a.
If input pressure is less than 130 psi, refer to vehicle TM (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
b.
If input pressure is 130 psi, turn off engine, relieve air system pressure and proceed to
Malfunction Faulty output air pressure.
MALFUNCTION
Faulty output air pressure.
CORRECTIVE ACTION
1.
Disconnect test gauge from input hose, and connect input hose to valve actuator.
2.
Disconnect air hose from stowage latch actuator and connect test gauge hose to air hose.
3.
Set battery disconnect switch to ON position and start engine.
4.
Press RETRIEVE button and check air output pressure from solenoid valve.
a.
If output pressure is less than 130 psi, replace solenoid valve (WP 0067).
b.
If output pressure equals 130 psi, replace stowage latch actuator (WP 0063).
END OF WORK PACKAGE
0057-3/blank