TM 10-3930-641-34-1
FUEL RATIO CONTROL ADJUSTMENT (CONT)
(Sheet 3 of 4)
LOCATION/ITEM
ACTION
REMARKS
7. Governor control lever
a. Rapidly move in FUEL-ON direction.
b. Read measurement on dial indicator.
NOTE
Read quickly and carefully because dial on in-
dicator will be at its peak for only a moment.
c. Dial indicator must read 0.070.
8. Valve (1)
a. Turn clockwise with cap (3) to increase
limited rack position.
b. Turn counterclockwise to decrease limited
rack position.
9. Steps (5) and (6)
Repeat until proper measurement is achieved.
10. Cover (3)
a. Aline with pin (2) in valve and turn to aline
with nearest capscrew holes after final
adjustment.
b. Secure with capscrews.
TA099011
Go on to Sheet 4
3-77