TM 10-3930-641-34-1
ALTERNATOR TESTING (CONT)
(Sheet 3 of 4)
LOCATION/ITEM
ACTION
REMARKS
OUTPUT CHECK
1. Rotor
first magnetize the rotor as follows:
a normal manner.
b. Momentarily connect a jumper lead from
the positive terminal of the battery to the
relay terminal as shown at lower right.
This procedure applies to both negative
and positive ground systems.
2. Battery
Battery must be fully charged.
3. Carbon pile
Must be turned off as you increase the
refer to the chart below.
SYSTEM
RATED
OPERATING
VOLTAGE
VOLTAGE
RANGE
12
14.0
13.0-15.0
24
28.0
26.0-30.0
32
37.5
33.0-39.0
If the voltage rises above the operating range
replace the voltage regulator. (See page 3-176).
TA 099060
Go on to Sheet 4
3-185