TM 10-3930-675-20-10043 00-5TOPHANDLER TILT TROUBLESHOOTING - CONTINUED0043 00Table 3. Error Code 237 - Tophandler Tilt Locking Control, Wiring Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 237 - Tophandler Tilt LockingControl, Wiring Circuit Failureb. If voltage is not present,enter “DIAG ATTACH-MENT 15 (16)” menu andcheck voltage of TILTOUTPUT. Voltage shouldchange from 0 to 24V andvice versa if “tilt locked”switch is activated/deactivated.a. If voltage is not as specified,replace ECU (791) (WP 007600).b. If voltage is not changing,notify SRA.Table 4. Error Code 261 - Tophandler Tilt OUT Control, Wiring Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 261 - Tophandler Tilt OUT Control,Wiring Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6010 fromtophandler tilt OUT solenoid.Place ignition switch to ONposition and perform voltagecheck.If 20-25V is present at connector6010, replace tilt OUT solenoid(WP 0169 00).3. Disconnect connector X188from tophandler junction boxon boom. Place ignitionswitch to ON position andperform voltage checkbetween connector X188 pinE and pin F.a. If 20-25V is present, checkcontinuity between con-nector X188 pin E andconnector 6010 pin 1;between connector X188pin F and connector 6010pin 2; and betweenconnector X188 pin F andECU (791) connector 3 pin4.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.DIAG TOP LIFT 13(16)OUTPUT/INPUTTILT IN 0mA0mATILT OUT 0mA0mA
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business