TM 10-3930-675-20-10043 00-7TOPHANDLER TILT TROUBLESHOOTING - CONTINUED0043 00Table 5. Error Code 262 - Tophandler Tilt OUT Control, Component FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 262 - Tophandler Tilt OUT Control,Component Failure - Continued4. Enter “DIAG ATTACH-MENT 13 (16)” menu andcheck current of TILT OUTOUTPUT. Current should bepresent with joystickactivated to tilt tophandlerout.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 6. Error Code 264 - Tophandler Tilt IN Control, Wiring Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 264 - Tophandler Tilt IN Control,Wiring Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6011 fromtophandler tilt IN solenoid.Place ignition switch to ONposition and perform voltagecheck.If 20-25V is present at connector6011, replace tilt IN solenoid(WP 0169 00).3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to ON position andperform voltage checkbetween connector X188 pinG and pin H.a. If 20-25V is present, checkcontinuity between con-nector X188 pin G andconnector 6011 pin 1;between connector X188pin H and connector 6011pin 2; and betweenconnector X188 pin H andECU (791) connector 3 pin12.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.DIAG TOP LIFT 13(16)OUTPUT/INPUTTILT IN 0mA0mATILT OUT 0mA0mA