TM 10-3930-675-20-10043 00-8TOPHANDLER TILT TROUBLESHOOTING - CONTINUED0043 00Table 6. Error Code 264 - Tophandler Tilt IN Control, Wiring Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 264 - Tophandler Tilt IN Control,Wiring Circuit Failure - Continuedb. If voltage is not present,enter “DIAG ATTACH-MENT 13 (16)” menu andcheck current of TILT INOUTPUT. Current shouldbe present with joystickactivated to tilt tophandlerin.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 7. Error Code 265 - Tophandler Tilt IN Control, Component Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 265 - Tophandler Tilt IN Control,Component Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6011 fromtophandler tilt IN solenoid.Place ignition switch to ONposition. Error code 264 willbe displayed. Perform voltagecheck.If 20-25V is present at connector6011, replace tilt IN solenoid(WP 0169 00).3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to OFF position andcheck continuity betweenconnector 6011 pin 1 and pin2 and between connector6011 pin 1 and pin 2 andchassis.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.4. Enter “DIAG ATTACH-MENT 13 (16)” menu andcheck current of TILT INOUTPUT. Current should bepresent with joystickactivated to tilt tophandler in.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.DIAG TOP LIFT 13(16)OUTPUT/INPUTTILT IN 0mA0mATILT OUT 0mA0mA
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business