TM 10-3930-675-20-1
0043 00-6
TOPHANDLER TILT TROUBLESHOOTING - CONTINUED
0043 00
Table 4. Error Code 261 - Tophandler Tilt OUT Control, Wiring Circuit Failure
Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 261 - Tophandler Tilt OUT Control,
Wiring Circuit Failure
b. If voltage is not present,
enter DIAG ATTACH-
MENT 13 (16) menu and
check current of TILT OUT
OUTPUT. Current should
be present with joystick
activated to tilt tophandler
out.
a. If current is not present,
replace ECU (791) (WP 0076
00).
b. If current is present, notify
SRA.
Table 5. Error Code 262 - Tophandler Tilt OUT Control, Component Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 262 - Tophandler Tilt OUT Control,
Component Failure
1. Check wires and cables from
tophandler control valve to
boom for obvious damage.
Repair or replace damaged
connectors (WP 0111 00).
2. Disconnect
electrical
connector
6010
from
tophandler tilt OUT solenoid.
Place ignition switch to ON
position. Error code 261 will
be displayed. Perform voltage
check.
If 20-25V is present at connector
6010, replace tilt OUT solenoid
(WP 0169 00).
3. Disconnect connector X188
from tophandler junction box
at end of boom. Place ignition
switch to OFF position and
check continuity between
connector 6010 pin 1 and pin
2 and between connector
6010 pin 1 and pin 2 and
chassis.
a. If continuity is not present,
repair or replace connectors
(WP 0111 00).
b. If wiring harness requires
replacement,
notify
DS
Maintenance.
DIAG TOP LIFT 13(16)
OUTPUT/INPUT
TILT IN 0mA
0mA
TILT OUT 0mA
0mA