TM 10-3930-675-20-10046 00-2TOPHANDLER SPREADER TROUBLESHOOTING - CONTINUED0046 00Table 1. Error Code 231 - Tophandler Spreader Opening, Open Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 231 - Tophandler Spreader Opening,Open Circuit Failure - Continueda. If 20-25V is present, checkcontinuity between con-nector X188 pin J andconnector 6018 pin 1;between connector X188pin K and connector 6018pin 2; and betweenconnector X188 pin K andECU (791) connector 2 pin4.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.b. If voltage is not present,enter “DIAG ATTACH-MENT 8 (16)” menu andcheck current of 20’-40’OUTPUT. Current shouldbe present with joystickactivated to opentophandler spreader.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 2. Error Code 232 - Tophandler Spreader Opening, Short Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 232 - Tophandler Spreader Opening,Short Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6018 fromtophandler spreader openingsolenoid. Place ignitionswitch to ON position. Errorcode 231 will be displayed.Perform voltage check at pins1 and 2.If 20-25V is present at connector6018, replace spreader openingsolenoid (WP 0169 00).DIAG TOP LIFT 8(16)OUTPUT INPUT20’->40’ 0mA 0mA 40’->20’ 0mA 0mA