TM 10-3930-675-20-10046 00-4TOPHANDLER SPREADER TROUBLESHOOTING - CONTINUED0046 00Table 3. Error Code 234 - Tophandler Spreader Closing, Open Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 234 - Tophandler Spreader Closing,Open Circuit Failure - Continued3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to ON position andperform voltage checkbetween connector X188 pinL and pin M.a. If 20-25V is present, checkcontinuity between con-nector X188 pin L andconnector 6019 pin 1;between connector X188pin M and connector 6019pin 2; and betweenconnector X188 pin M andECU (791) connector 2 pin12.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.b. If voltage is not present,enter “DIAG ATTACH-MENT 8 (16)” menu andcheck current of 20’-40’OUTPUT. Current shouldbe present with joystickactivated to closetophandler spreader.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 4. Error Code 235 - Tophandler Spreader Closing, Short Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 235 - Tophandler Spreader Closing,Short Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6019 fromtophandler spreader closingsolenoid. Place ignitionswitch to ON position. Errorcode 234 will be displayed.Perform voltage check at pins1 and 2.If 20-25V is present at connector6019, replace spreader closingsolenoid (WP 0169 00).DIAG TOP LIFT 8(16)OUTPUT INPUT20’->40’ 0mA 0mA 40’->20’ 0mA 0mA
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business