TM 10-3930-675-20-10046 00-3TOPHANDLER SPREADER TROUBLESHOOTING - CONTINUED0046 00Table 2. Error Code 232 - Tophandler Spreader Opening, Short Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 232 - Tophandler Spreader Opening,Short Circuit Failure - Continued3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to OFF position andcheck continuity betweenconnector 6018 pin 1 and pin2 and between connector6018 pin 1 and pin 2 andchassis.a. If continuity is present, repairor replace connectors (WP0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.4. Enter “DIAG ATTACH-MENT 8 (16)” menu andcheck current of 20’-40’OUTPUT. Current should bepresent with joystickactivated to open tophandlerspreader.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 3. Error Code 234 - Tophandler Spreader Closing, Open Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 234 - Tophandler Spreader Closing,Open Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6019 fromtophandler spreader closingsolenoid. Place ignitionswitch to ON position andperform voltage check at pins1 and 2.If 20-25V is present at connector6019, replace spreader closingsolenoid (WP 0169 00).DIAG TOP LIFT 8(16)OUTPUT INPUT20’->40’ 0mA 0mA 40’->20’ 0mA 0mA