TM 10-3930-675-20-10047 00-2TOPHANDLER TWISTLOCKS AND FORKLIFT SENSOR TROUBLESHOOTING - CONTINUED0047 00Table 1. Error Code 212 - Tophandler Left Twistlocks Indication Failure Troubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 212 - Tophandler Left TwistlocksIndication Failure - Continued3. Remove tophandler junctionbox cover and ensure thatcircuit breakers F41, F42, andF43 are not tripped. Checkwire from circuit breaker F42to connector X181 fordamage.a. Reset circuit breakers asrequired (WP 0076 00).b. Replace damaged connectors(WP 0111 00).4. Remove junction box X183cover (located on left end oftophandler) and checkvoltage between connectorX183 pin 3 and pin 4. Voltageshould be 20-25V.a. If voltage is present,perform functional checkof left side twistlockproximity switches byplacing a metal objectwithin 5 mm of tip of eachswitch. Proximity switchindicator light shouldilluminate.If indicator lights do notilluminate, replace proximityswitch (WP 0074 00).b. If indicator lightsilluminate, check voltage atjunction box X183 pin 5(for unlocked) and pin 6(for locked).If voltage is not present, replaceproximity switch (WP 0074 00).5. Remove cover from junctionbox X182 (located on top oftophandler). Check voltagebetween junction box X182pin 4 and pin 5. Voltageshould be 20-25V.If voltage is not as specified,repair or replace cable fromjunction box X183 to connectorX182 (WP 0111 00).6. Check continuity betweenjunction box X182 pin 8 andjunction box X183 pin 5 andbetween junction box X182pin 9 and junction box X183pin 6.If continuity is not present,repair or replace cable fromjunction box X183 to connectorX182 (WP 0111 00).