TM 10-3930-675-20-1
0047 00-6
TOPHANDLER TWISTLOCKS AND FORKLIFT SENSOR TROUBLESHOOTING - CONTINUED
0047 00
Table 3. Error Code 214 - Tophandler Forklift Sensor Indication Failure
Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 214 - Tophandler Forklift Sensor
Indication Failure - Continued
6. Check continuity between
junction box X182 pin 2 and
junction box X183 pin 7 and
between junction box X182
pin 3 and junction box X183
pin 8.
If continuity is not present,
repair or replace cable from
junction box X183 to junction
box X182 (WP 0111 00).
7. Disconnect connector X181
from tophandler junction box
located at end of boom. Check
voltage between junction box
pin A and pin B. Voltage
should be 20-25V.
a. If voltage is not as specified,
repair cable from connector
X181 to junction box X182
(WP 0111 00).
b. If wiring harness must be
replaced,
notify
DS
Maintenance.
8. Check continuity between
junction box X182 pin 2 and
connector X181 pin M and
between junction box X182
pin 3 and connector X181 pin
N.
a. If continuity is not present,
repair or replace cable from
connector X181 to junction
box X182 (WP 0111 00).
b. If wiring harness must be
replaced,
notify
DS
Maintenance.
Table 4. Error Code 243 - Tophandler Twistlock Locking Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 243 - Tophandler Twistlock Locking
Circuit Failure
1. Check wires and cables from
tophandler control valve to
boom for obvious damage.
Repair or replace damaged wires
(WP 0111 00).
2. Disconnect
electrical
connector
6040
from
tophandler twistlock locking
solenoid.
Place
ignition
switch to ON position and
perform voltage check at pins
1 and 2.
If 20-25V is present at connector
6040, replace twistlock locking
solenoid (WP 0169 00).
DIAG TOP LIFT 6(16)
TW-LOCK OUTPUT INPUT
UNLOCKED 0.00V
0Ma
LOCKED 0.00V
0mA