TM 10-3930-675-20-1
0006 00-10
TROUBLESHOOTING PROCEDURES (NON-ERROR CODE) - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures (Non-Error Code) - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BOOM AND TOPHANDLER WORK LIGHTS
11. Work Light(s) Do Not Operate When Switch
is Turned On.
1. Check position of blackout
drive/marker light switch.
Place blackout drive/marker light
switch in OFF position.
2. Ensure that work light circuit
breaker numbers 12 and 17 are
not tripped.
Reset circuit breakers as required
(WP 0073 00).
3. Inspect work lights for damage
or burned out lamps.
a. Replace burned out lamps
(WP 0084 00).
b. Replace damaged work light
(WP 0084 00).
4. Check work light wiring
harnesses and connectors for
damage,
continuity,
and
proper voltage (WP 0199 00-
46 and WP 0199 00-28).
Repair or replace damaged wires
or connectors (WP 0111 00).
5. Check instrument panel rocker
switches for damage and
continuity (WP 0199 00-46).
Replace damaged rocker switch
(WP 0072 00).
6. Remove work light relay
number 3013 (RL4) and check
for shorted or damaged relay.
Replace shorted or damaged
relay (WP 0073 00).
BOOM INFRARED (IR) WORK LIGHTS
12. IR Work Light(s) Do Not Operate When
Switch is Turned On.
1. Ensure that IR and work light
circuit breaker numbers 16
and 12 are not tripped.
Reset circuit breakers as required
(WP 0073 00).
2. Inspect IR lights for damage.
Replace damaged IR light (WP
0089 00).
3. Check
IR
light
wiring
harnesses and connectors for
damage,
continuity,
and
proper voltage (WP 0199 00-
46).
Repair or replace damaged wires
or connectors (WP 0111 00).
4. Remove IR and work light
relay number 3013 (RL4) and
check for shorted or damaged
relay.
Replace shorted or damaged
relay (WP 0073 00).
5. Check instrument panel rocker
switches for damage and
continuity (WP 0199 00-46).
Replace damaged rocker switch
(WP 0072 00).