TM 10-3930-675-20-10006 00-10TROUBLESHOOTING PROCEDURES (NON-ERROR CODE) - CONTINUED0006 00Table 2. Electrical Troubleshooting Procedures (Non-Error Code) - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONBOOM AND TOPHANDLER WORK LIGHTS11. Work Light(s) Do Not Operate When Switchis Turned On.1. Check position of blackoutdrive/marker light switch.Place blackout drive/marker lightswitch in OFF position.2. Ensure that work light circuitbreaker numbers 12 and 17 arenot tripped.Reset circuit breakers as required(WP 0073 00).3. Inspect work lights for damageor burned out lamps.a. Replace burned out lamps(WP 0084 00).b. Replace damaged work light(WP 0084 00).4. Check work light wiringharnesses and connectors fordamage, continuity, andproper voltage (WP 0199 00-46 and WP 0199 00-28).Repair or replace damaged wiresor connectors (WP 0111 00).5. Check instrument panel rockerswitches for damage andcontinuity (WP 0199 00-46).Replace damaged rocker switch(WP 0072 00).6. Remove work light relaynumber 3013 (RL4) and checkfor shorted or damaged relay.Replace shorted or damagedrelay (WP 0073 00).BOOM INFRARED (IR) WORK LIGHTS12. IR Work Light(s) Do Not Operate WhenSwitch is Turned On.1. Ensure that IR and work lightcircuit breaker numbers 16and 12 are not tripped.Reset circuit breakers as required(WP 0073 00).2. Inspect IR lights for damage. Replace damaged IR light (WP0089 00).3. Check IR light wiringharnesses and connectors fordamage, continuity, andproper voltage (WP 0199 00-46).Repair or replace damaged wiresor connectors (WP 0111 00).4. Remove IR and work lightrelay number 3013 (RL4) andcheck for shorted or damagedrelay.Replace shorted or damagedrelay (WP 0073 00).5. Check instrument panel rockerswitches for damage andcontinuity (WP 0199 00-46).Replace damaged rocker switch(WP 0072 00).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business