TM 10-3930-675-20-2
0060 00-7
ETHER COLD START SYSTEM MAINTENANCE - CONTINUED
0060 00
COLD START ACTIVATION SOLENOID INSTALLATION - CONTINUED
3.
Install elbow to bottom of solenoid (4).
4.
Connect other end of ether supply tube (9) to elbow.
5.
Position solenoid (4) to mounting bracket (10) and install two washers (8) and screws (7).
6.
Connect connector (12) of solenoid harness to wiring harness connector (11).
7.
Install canister (refer to Ether Canister Installation).
8.
Install new tiedown straps.
9.
Install engine cover (WP 0143 00).
END OF WORK PACKAGE
11
12