TM 10-3930-675-20-20060 00-4ETHER COLD START SYSTEM MAINTENANCE - CONTINUED0060 00COLD START ACTIVATION SOLENOID REMOVALNOTERemove and discard tiedown straps.1.Remove canister (refer to Ether Canister Removal).2.Disconnect connector (12) of solenoid harness from wiring harness connector (11).3.Disconnect ether supply tube (9) from elbow on underside of solenoid (4).4.Remove two screws (7), washers (8), and solenoid (4) from mounting bracket (10).5.Remove elbow from bottom of solenoid (4).1112