TM 10-3930-675-20-2
0060 00-2
ETHER COLD START SYSTEM MAINTENANCE - CONTINUED
0060 00
ETHER CANISTER REMOVAL - CONTINUED
2.
Inspect gasket (5) for damage. Remove and discard only if damaged.
ETHER CANISTER INSTALLATION
1.
Ensure gasket (5) is positioned inside top of solenoid (4).
2.
Position canister (1) inside clamp (2). Install to solenoid (4) by turning canister clockwise.
3.
Tighten clamp screw (3).
5
4