TM 10-3930-675-24-1
OVERLOAD PROTECTION TROUBLESHOOTING - CONTINUED
0011 00
Table 7. Error Code 136 - Right Lift Cylinder Piston Pressure Sensor or
Circuit Failure Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 136 - - Right Lift Cylinder Piston 5. Disconnect sensor harness a. If no voltage (24V) is found,
768-3 and check voltage (24V)
Pressure Sensor or Circuit Failure - Continued
continue with step 6.
between 1 and 3 with the b. If voltage (24V) is found,
check sensor pins and harness
for damage, seal, and tight fit.
c. Replace damaged sensor and
harness (WP 0102 00).
6. Remove the engine cover to a. If no voltage (24V) is found at
gain access to X167. Check
X167 between pins 16 and 17,
voltage (24V) at X167
between pins 16 and 17 and
check voltage (<2V) between b. If no voltage (24V) is found at
pins 17 and 20 with the ignition
X167 between pins 17 and 20,
9).
c. Replace damaged sensor and
harness (WP 0102 00).
d. Repair or replace damaged
wires or connectors (WP 0113
00).
e. Replace damaged or open
harness (WP 0113 00).
0011 00-12