TM 10-3930-675-24-2
TOPHANDLER PROXIMITY SWITCHES REPLACEMENT - CONTINUED
0075 00
TWISTLOCK PROXIMITY SWITCH INSTALLATION
1.
Position proximity switch (1) with cable on tophandler.
2.
Using a jeweler's screwdriver, connect proximity switch wires (8) to terminal blocks (7).
3.
Install grommet (9) and cable nut (10) on junction box (5). Tighten cable nut.
4.
Install cover (4) on junction box (5) and tighten four screws (6).
5.
Loosely install proximity switch (1) and two jamnuts (2) on mounting bracket (3).
CAUTION
Overtightening jamnuts will damage proximity switch threads.
NOTE
Plunger must be raised in order to properly make adjustment.
6.
Position proximity switch (1) so a gap of 0.20 in. (5 mm) is obtained. Tighten two jamnuts to 177 lb-in. (20 Nm).
2
1
3
5 MM
CONTAINER-
INDICATING
PLUNGER
7.
Install cable clamps and new tiedown straps as needed.
0075 00-3