TM 10-3930-675-24-2
AIR CONDITIONER FANS MAINTENANCE - CONTINUED
0196 00
RELAYS AND RESISTORS INSTALLATION
NOTE
Perform steps 1 and 2 to install each of two resistors.
1.
Install resistor (18) on cover (3) with two screws (17), washers (16), and new locknuts (15).
2.
Connect two connectors (19) of fan wiring harness (9) to resistor (18).
NOTE
Perform steps 3 and 4 to install two fan relays.
3.
Install terminal blocks (14) of fan wiring harness (9) on cover (3) with two screws (13), washers (12), and new locknuts
(11).
4.
Install two relays (10) on terminal blocks (14).
5.
Install cover (3) assembly on condenser fan box (1) and install ten screws (2).
1
2
3
END OF WORK PACKAGE
0196 00-5/(0196 00-6 Blank)