TM 55-8145-201-14
Table 3-1. Preventive Maintenance Checks and Services
NOTE: Within designated interval, these checks are to be performed in the order listed.
B Before
D During
A After
W Weekly
M - Monthly
INTERVAL
Item to be
Procedures
For Readiness Reporting
ITEM
Inspected
Check for and have repaired
Equipment Is Not
NO
B
D
A
WM
or adjusted as necessary
Ready/Available If:
1.
Container
Check for obvious damage and leaks.
they are not covered or plugged. Check
drain hoses under floor to insure they are
not damaged or kinked.
Check load to ensure that it is properly
stacked.
NOTE
There must be free flow of air into and out
space left on top of load and there must be
a free flow of air under and around the load.
Check door seals for damage.
2.
Temperature
Check for obvious damage.
Recorder
Check to ensure that the recorder is
operating. Wind unit or replace chart paper
as required and replace pen if not marking
3.
Refrigeration Unit
Check mounting bolts to container to
ensure they are tight.
Check electrical cable connections to
ensure they are tight.
Check for obvious damage and
Refrigerant low:
visible liquid leaks.
will not cool.
Check for unusual noises and excessive
vibrations.
Refer to TM 5-4110-231-14 for specific
items to inspect and ensure that the
refrigeration unit is operating properly.
3-2
Change 5