TM 9-3950-253-13&P
0011
ERROR CODE SUMMARY - Continued
Table 1. Enhanced Container Handling Unit (E-CHU) - Continued.
ERROR
COMMENTS/
POSSIBLE
TROUBLESHOOTING
DESCRIPTION
LOCATION
CODE
PROBLEM
ACTION
REFERENCE
31
Hout - Relay 2
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Hook Arm Up
After Fault
Malfunction
Sensor)
Rectified
32
Hout - Relay 3
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Middle Frame
After Fault
Malfunction
Down Sensor)
Rectified
33
Hout - Relay 4
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Free-flow
After Fault
Malfunction
Rectified
34
Hout - Relay 5
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Transit Valve)
After Fault
Malfunction
Rectified
35
Hout - Relay 6
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Hook Arm
After Fault
Malfunction
Rectified
36
Hout - Relay 7
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Middle Frame
After Fault
Malfunction
Rectified
37
Hout - Relay 8
Fuse Blown Due To
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Output (Hook Arm
After Fault
Malfunction
Rectified
CONFLICTS
C0
Middle Frame
Signals Present From
Hook Lift
Check Both
Refer to No Hook Lift
Sensor Conflict
Both Sensors On the
Sensors -
Middle Frame
Replace If
Malfunction
Necessary
C1
Hook Arm
Signals Present From
Hook Lift
Check Both
Refer to No Hook Lift
Sensor Conflict
Both Sensors On The
Sensors -
Hook Arm
Replace If
Malfunction
Necessary
0011-18