31
Hout - Relay 2
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0038)
Output (Hook Arm Up
After Fault
Malfunction
Sensor)
Rectified
32
Hout - Relay 3
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0039)
Output (Middle Frame
After Fault
Malfunction
Down Sensor)
Rectified
33
Hout - Relay 4
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0040)
Output (Free-flow
After Fault
Malfunction
Solenoid)
Rectified
34
Hout - Relay 5
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0041)
Output (Transit Valve)
After Fault
Malfunction
Rectified
35
Hout - Relay 6
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0042)
Output (Hook Arm
After Fault
Malfunction
Unload Solenoid)
Rectified
36
Hout - Relay 7
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0043)
Output (Middle Frame
After Fault
Malfunction
Load Solenoid)
Rectified
37
Hout - Relay 8
Fuse Blown Due To
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0044)
Output (Hook Arm
After Fault
Malfunction
Load Solenoid)
Rectified
CONFLICTS
C0
Middle Frame
Signals Present From
Hook Lift
Check Both
Refer to No Hook Lift
Sensor Conflict
Both Sensors On the
Sensors -
Function (WP 0049)
Middle Frame
Replace If
Malfunction
Necessary
C1
Hook Arm
Signals Present From
Hook Lift
Check Both
Refer to No Hook Lift
Sensor Conflict
Both Sensors On The
Sensors -
Function (WP 0050)
Hook Arm
Replace If
Malfunction
Necessary