TM 9-3950-253-13&P
0011
ERROR CODE SUMMARY - Continued
Table 1. Enhanced Container Handling Unit (E-CHU) - Continued.
ERROR
COMMENTS/
POSSIBLE
TROUBLESHOOTING
DESCRIPTION
LOCATION
CODE
PROBLEM
ACTION
REFERENCE
Sensor) P6:2 (Middle
Frame 134 in. and
Hook Arm 77 in.
Sensors)
2
Fuse
Fuse Blown Due To
Space 4000
Fuse Will
Refer to No Stowage
Short Circuit on P5
ST Box
Auto Reset
(Angle Sensor)
After Fault
Malfunction
Rectified
5
Column Fuse
Fuse Blown Due To
Space 4000
Fuse Will
Refer to No Stowage
Short Circuit on P5
ST Box
Auto Reset
(Angle Sensor)
After Fault
Malfunction
Rectified
6
Terminal Fuse
Fuse Blown Due To
Space 4000
Fuse Will
Refer to No Stowage
Short Circuit on P3
ST Box
Auto Reset
(Service Terminal
After Fault
Malfunction
Connection)
Rectified
7
CAN Fuse
Fuse Blown Due To
Any Position
Fuse Will
Refer to No Stowage
Short Circuit on CAN
Auto Reset
Bus (5V Missing)
After Fault
Malfunction
Rectified
8
Internal Error
Internal Error on
Space 4000
Replace
Refer to Stowage
Stowage Control Box
ST Box
Space 4000
Movement Is Irregular
ST Box If
Error Repeats
9
Pressure Sensor Values From Angle
Space 4000
Check
Refer to No Stowage
Sensor Not Legal
ST Box
Connection/
Setting/
Malfunction
Replace
Sensor
10
Parameter
Internal Parameter
Space 4000
Check
Refer to Stowage
Error - Default
ST Box
Parameters/
Movement Is Irregular
Parameters Have
Reset/
Been Restored
Replace
Space 4000
ST Box
11
Hin 1 Time Out
CAN Bus Not Able to
Any Position
Check
Refer to No Stowage
Communicate With
Box/CAN Bus
Additional MUX Box
Wire and
Malfunction
Replace if
Necessary
0011-16
03/15/2011Rel(1.10)root(tsintrowp)wpno(T582011)