TM 9-3950-253-13&P
FIELD MAINTENANCE
NO STOWAGE FUNCTION - ERROR CODE 5
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic s (WP 0118, Table 2,
Vehicle parked on level ground, in neutral gear
Item 2)
with parking brake applied (PLS:
TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P)
References
TROUBLESHOOTING PROCEDURE
SYMPTOM
ERROR CODE 5
MALFUNCTION
Faulty stowage angle sensor.
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
2.
Disconnect stowage angle sensor harness from stowage angle sensor (WP 0075).
NOTE
When ignition switch is turned on after battery disconnect switch has been turned
off and back on, error codes 1 and 24 may alternately display for one minute.
This error code indicates that temporary settings were lost while battery
disconnect switch was off, and is consistent with normal operation.
3.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is not displayed, replace stowage angle sensor (WP 0075).
b.
If error code displayed, proceed to Malfunction Stowage angle harness short circuit.
MALFUNCTION
Stowage angle harness short circuit.
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position.
2.
Disconnect wires from positions 1, 2, and 3 on P5 in Space 4000 ST box.
3.
Set battery disconnect switch and ignition switch to ON position to reset power.
0030-1
03/15/2011Rel(1.10)root(tswp)wpno(T582029)