TM 9-3950-253-13&P
FIELD MAINTENANCE
NO STOWAGE FUNCTION - ERROR CODE 2
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic s (WP 0118, Table 2,
Vehicle parked on level ground, in neutral gear
Item 2)
with parking brake applied
(PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P)
References
TROUBLESHOOTING PROCEDURE
SYMPTOM
ERROR CODE 2
MALFUNCTION
Failed fuse.
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
2.
Check 15 amp fuse in relay box.
NOTE
When ignition switch is turned on after battery disconnect switch has been
turned off and back on, error codes 1 and 24 may alternately display for one
minute. This error code indicates that temporary settings were lost while
battery disconnect switch was off, and is consistent with normal operation.
a.
Replace 15 amp fuse in relay box and set battery disconnect switch and ignition switch to
ON position.
b.
If error code is still displayed, continue to Malfunction Faulty stowage latch solenoid valve.
MALFUNCTION
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position.
2.
3.
Set battery disconnect switch and ignition switch to ON position.
0029-1