TM 9-3950-253-13&P
0028
CORRECTIVE ACTION - Continued
2.
Disconnect wiring harnesses from middle frame sensor, hook arm sensor, stowage angle
3.
Set battery disconnect switch and ignition switch to ON position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
a.
If error code 0 or 1 is still displayed, proceed to Symptom ERROR CODE 0 AND 1 AFTER
POWER RESET.
b.
If error code 0 or 1 is not displayed, proceed to step 4.
4.
Set ignition switch and battery disconnect switch to OFF position.
5.
Connect right side stowage guide sensor harness to right side stowage guide sensor
6.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is displayed, replace right side stowage guide sensor (WP 0075).
b.
If no error code, proceed to step 7.
7.
Set ignition switch and battery disconnect switch to OFF position.
8.
Connect left side stowage guide sensor harness to left side stowage guide sensor (WP 0075).
9.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is displayed, replace left side stowage guide sensor (WP 0075).
b.
If no error code, proceed to step 10.
10.
Set ignition switch and battery disconnect switch to OFF position.
11.
Connect angle sensor harness to angle sensor (WP 0075).
12.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is displayed, replace angle sensor (WP 0075).
b.
If no error code, proceed to step 13.
13.
Set ignition switch and battery disconnect switch to OFF position.
14.
Connect hook arm sensor harness to hook arm sensor (WP 0075).
15.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is displayed, replace hook arm sensor (WP 0075).
b.
If no error code, proceed to step 16.
16.
Set ignition switch and battery disconnect switch to OFF position.
17.
Connect middle frame sensor harness to middle frame sensor (WP 0075).
18.
Set battery disconnect switch and ignition switch to ON position.
If error code is displayed, replace middle frame sensor (WP 0075).
SYMPTOM
ERROR CODE 0 AND 1 AFTER POWER RESET
0028-2
03/15/2011Rel(1.10)root(tswp)wpno(T582027)