• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
'Unknown' by Unknown - Page 156 of 720
'Unknown' by Unknown - Page 158 of 720

PALLETIZED LOAD SYSTEM TRUCK, M1075 AND M1075A1 (PLS) AND HEAVY EXPANDED MOBILITY TACTICAL TRUCK, M1120, M1120A2, AND M1120A4 ENHANCED CONTAINER HANDLING UNIT
Page Navigation
  106    107    108    109    110  111  112    113    114    115    116  
img
. . . . . . . .
TM 9-3950-253-13&P
0011
ERROR CODE SUMMARY - Continued
Table 1. Enhanced Container Handling Unit (E-CHU) - Continued.
ERROR
COMMENTS/
POSSIBLE
TROUBLESHOOTING
DESCRIPTION
LOCATION
CODE
PROBLEM
ACTION
REFERENCE
12
Hin 2 Time Out
CAN Bus Not Able to
Any Position
Check
Refer to No Stowage
Communicate With
Box/CAN Bus
Function (WP 0034)
Stowage MUX Box
Wire and
Malfunction
(Control Panel)
Replace if
Necessary
Refer to No Stowage
14
Hour Time Out
CAN Bus Not Able to
Any Position
Check
Box/CAN Bus
Function (WP 0034)
Communicate With
Wire and
Malfunction
Output Box
Replace if
Necessary
17
Hin 1 Fuse
Fuse Blown Due to
Additional
Fuse Will
Refer to No Stowage
Short Circuit On Any
MUX Box
Auto Reset
Function (WP 0035)
Inputs
After Fault
Malfunction
Rectified
18
Hin 2 Fuse
Fuse Blown Due to
Stowage MUX Fuse Will
Refer to No Stowage
Short Circuit On Any
Box (Control
Auto Reset
Function (WP 0035)
Inputs
Panel)
After Fault
Malfunction
Rectified
20
Hour Error
Short Circuit On Any
Relay Box
Auto Reset on Refer to Total Stop of
Output or Box Fuse or
Outputs/
System (WP 0047)
Supply Missing
Replace Box
Malfunction
Fuse
22
Not Running
Program Has Stopped Space 4000
Power Off/
Refer to Total Stop of
Running
ST Box
Power On To
System (WP 0048)
Reset
Malfunction
23
CAN Buffer
CAN Bus Not Able To
Any Position
Check
Refer to No Stowage
Over Run
Communicate With
Box/CAN Bus
Function (WP 0034)
Any Box
Wire and
Malfunction
Replace if
Necessary
24
Real Time Lost
Code May Be
Space 4000
None
Displayed For 1
ST Box
Minute After Power
On
30
Hout - Relay 1
Fuse Blown Due to
Relay Box
Fuse Will
Refer to No Stowage
Fuse
Short Circuit On Relay
Auto Reset
Function (WP 0037)
Output (Stowage
After Fault
Malfunction
Latch)
Rectified
0011-17
03/15/2011Rel(1.10)root(tsintrowp)wpno(T582011)


Privacy Statement