TM 9-3950-253-13&P
FIELD MAINTENANCE
NO STOWAGE FUNCTION - ERROR CODE 17
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic s (WP 0118, Table 2,
Vehicle parked on level ground, in neutral gear
Item 2)
with parking brake applied
(PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P)
References
NOTE
When ignition switch is turned on after battery disconnect switch has been turned off and
back on, error codes 1 and 24 may alternately display for one minute. This error code
indicates that temporary settings were lost while battery disconnect switch was off, and is
consistent with normal operation.
TROUBLESHOOTING PROCEDURE
SYMPTOM
ERROR CODE 17
MALFUNCTION
Faulty stowage interface loom.
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
2.
Disconnect wire 1465 from position 3 on P3 in Additional MUX box.
3.
Disconnect wire 1467 from position 3 on P4 in Additional MUX box.
4.
Disconnect wire 1468 from position 3 on P5 in Additional MUX box.
5.
Disconnect wire 1464 from position 3 on P6 in Additional MUX box.
6.
Disconnect wire 1463 from position 3 on P7 in Additional MUX box.
7.
Disconnect wire 1462 from position 3 on P8 in Additional MUX box.
8.
Disconnect wire 1469 from position 3 on P9 in Additional MUX box.
9.
Disconnect wire 1466 from position 3 on P10 in Additional MUX box.
10.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is still displayed, replace Additional MUX box (WP 0070).
0035-1
03/15/2011Rel(1.10)root(tswp)wpno(T582034)