FIELD MAINTENANCE
NO STOWAGE FUNCTION - ERROR CODE 18
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic s (WP 0118, Table 2,
Vehicle parked on level ground, in neutral gear
Item 2)
with parking brake applied
(PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P)
References
WP 0070
WP 0075
NOTE
When ignition switch is turned on after battery disconnect switch has been turned off and
back on, error codes 1 and 24 may alternately display for one minute. This error code
indicates that temporary settings were lost while battery disconnect switch was off, and is
consistent with normal operation.
TROUBLESHOOTING PROCEDURE
SYMPTOM
ERROR CODE 18
MALFUNCTION
Faulty twistlock sensor harness.
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
2.
Disconnect LH twistlock sensor harness from LH twistlock sensor (WP 0075).
3.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is not displayed, replace LH twistlock sensor (WP 0075).
b.
If error code is still displayed, proceed to Step 4.
4.
Set ignition switch and battery disconnect switch to OFF position.
5.
Disconnect RH twistlock sensor harness from RH twistlock sensor (WP 0075).
6.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is not displayed, replace RH twistlock sensor (WP 0075).
b.
If error code is still displayed, proceed to Step 7.
7.
Set ignition switch and battery disconnect switch to OFF position.
8.
Disconnect wires from positions 1, 2 and 3 on P9 in stowage MUX box (control panel).