PALLETIZED LOAD SYSTEM TRUCK, M1075 AND M1075A1 (PLS) AND HEAVY EXPANDED MOBILITY TACTICAL TRUCK, M1120, M1120A2, AND M1120A4 ENHANCED CONTAINER HANDLING UNIT
Page Navigation
  156    157    158    159    160  161  162    163    164    165    166  
img
. . .
TM 9-3950-253-13&P
0038
CORRECTIVE ACTION - Continued
8.
Connect vehicle wiring harness to stowage interface loom, and connect stowage interface loom
to vehicle control box (WP 0070).
9.
Disconnect wire 1466 from pin 2 on P4 in relay box.
10.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is not displayed, replace stowage interface loom (WP 0070).
b.
If error code is displayed, replace relay box (WP 0070).
END OF WORK PACKAGE
0038-2
03/15/2011Rel(1.10)root(tswp)wpno(T582037)