PALLETIZED LOAD SYSTEM TRUCK, M1075 AND M1075A1 (PLS) AND HEAVY EXPANDED MOBILITY TACTICAL TRUCK, M1120, M1120A2, AND M1120A4 ENHANCED CONTAINER HANDLING UNIT
Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
. . .
TM 9-3950-253-13&P
0039
CORRECTIVE ACTION - Continued
8.
Connect vehicle wiring harness to stowage interface loom, and connect stowage interface loom
to vehicle control box (WP 0070).
9.
Disconnect wire 1469 from pin 2 on P5 in relay box.
10.
Set battery disconnect switch and ignition switch to ON position.
a.
If error code is not displayed, replace stowage interface loom (WP 0070).
b.
If error code is displayed, replace relay box (WP 0070).
END OF WORK PACKAGE
0039-2