TM 9-3950-253-13&P
0034
CORRECTIVE ACTION - Continued
23.
Measure resistance of wire 5 in Space 4000 ST box to wire 7 in relay box. Resistance should be
<200 Ohms.
a.
If resistance is >200 Ohms, replace CAN bus linking harness between relay box and
b.
MALFUNCTION
Faulty stowage MUX box.
CORRECTIVE ACTION
Set battery disconnect switch and ignition switch to ON position.
If error code is still displayed, replace stowage MUX box (Control Panel) (WP 0070).
MALFUNCTION
Faulty stowage Additional MUX box and relay box.
CORRECTIVE ACTION
Set battery disconnect switch and ignition switch to ON position.
If error code is still displayed, replace stowage Additional MUX box and relay box
END OF WORK PACKAGE
0034-3/blank
03/15/2011Rel(1.10)root(tswp)wpno(T582033)