TM 9-3950-253-13&P
FIELD MAINTENANCE
TOTAL STOP OF SYSTEM - ERROR CODE 22
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic s (WP 0118, Table 2,
Vehicle parked on level ground, in neutral gear
Item 2)
with parking brake applied
(PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P)
References
NOTE
When ignition switch is turned on after battery disconnect switch has been turned off and
back on, error codes 1 and 24 may alternately display for one minute. This error code
indicates that temporary settings were lost while battery disconnect switch was off, and is
consistent with normal operation.
TROUBLESHOOTING PROCEDURE
SYMPTOM
ERROR CODE 22
MALFUNCTION
Faulty control box interface loom.
CORRECTIVE ACTION
1.
Set ignition switch and battery disconnect switch to OFF position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
2.
Set battery disconnect switch and ignition switch to ON position and start engine.
Attempt to operate system. If error code is still displayed, replace Space 4000 ST Box
END OF WORK PACKAGE
0048-1/blank
03/15/2011Rel(1.10)root(tswp)wpno(T582047)