TM 9-3950-253-13&P
FIELD MAINTENANCE
NO STOWAGE FUNCTION - ERROR CODE C3
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic s (WP 0118, Table 2,
Vehicle parked on level ground, in neutral gear
Item 2)
with parking brake applied
(PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P)
References
NOTE
When ignition switch is turned on after battery disconnect switch has been turned off and
back on, error codes 1 and 24 may alternately display for one minute. This error code
indicates that temporary settings were lost while battery disconnect switch was off, and is
consistent with normal operation.
TROUBLESHOOTING PROCEDURE
SYMPTOM
ERROR CODE C3
MALFUNCTION
Internal error in stowage MUX box (control panel).
CORRECTIVE ACTION
1.
Turn vehicle off and set battery disconnect switch to OFF position (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
2.
Set battery disconnect switch to ON position and start vehicle (PLS: TM 9-2320-364-14&P,
HEMTT: TM 9-2320-326-14&P).
If error code is still displayed, replace stowage MUX box (control panel) (WP 0070).
END OF WORK PACKAGE
0045-1/blank